    PARAMETER PVI-3.0-TL-OUTD PVI-3.6-TL-OUTD PVI-4.2-TL-OUTD
    Input Side
    Absolute Maximum DC Input Voltage (Vmax,abs) 600 V
    Start-up DC Input Voltage (Vstart) 200 V (adj. 120...350 V)
    Operating DC Input Voltage Range (Vdcmin...Vdcmax) 0.7 x Vstart...580 V
    Rated DC Input Power (Pdcr) 3120 W 3750 W 4375 W
    Number of Independent MPPT 2
    Maximum DC Input Power for each MPPT (PMPPTmax) 2000 W 3000 W
    DC Input Voltage Range with Parallel Configuration of MPPT at Pacr 160...530 V 120...530 V 140...530 V
    DC Power Limitation with Parallel Configuration of MPPT Linear Derating From MAX to Null [530V≤VMPPT≤580V]
    DC Power Limitation for each MPPT with Independent
    Configuration of MPPT at Pacr , max unbalance example
    2000 W [200V≤VMPPT≤530V]
    the other channel: Pdcr-2000W
    [112V≤VMPPT≤530V]
    3000 W [190V≤VMPPT≤530V]
    the other channel: Pdcr-3000W [90V≤VMPPT≤530V]
    Maximum DC Input Current (Idcmax) / for each MPPT (IMPPTmax) 20.0 A / 10.0 A 32.0 A / 16.0 A
    Maximum Input Short Circuit Current for each MPPT 12.5 A 20.0 A
    Number of DC Inputs Pairs for each MPPT 1 2 for MPPT1 and 1 for MPPT2
    DC Connection Type Tool Free PV Connector WM / MC4
    Input Protection
    Reverse Polarity protection Yes, from limited current source
    Input Over Voltage Protection for each MPPT - Varistor 2
    Photovoltaic Array Isolation Control According to local standard
    DC Switch Rating for each MPPT (-S Version) 25 A / 600 V
    Output Side
    AC Grid Connection Type Single phase
    Rated AC Power (Pacr) 3000 W 3600 W 4200 W
    Maximum AC Output Power (Pacmax) 3300 W 4000 W 4600 W
    Rated AC Grid Voltage (Vac,r) 230 V
    AC Voltage Range 180...264 V(1)
    Maximum AC Output Current (Iac,max) 14.5 A 17.2 A (2) 20.0 A
    Rated Output Frequency (fr) 50 Hz
    Output Frequency Range (fmin...fmax) 47...53 Hz (3)
    Nominal Power Factor (Cosphiac,r) > 0.995
    Total Current Harmonic Distortion < 3.5 %
    AC Connection Type Screw terminal block
    Output Protection
    Anti-Islanding Protection According to local standard
    Maximum AC Overcurrent Protection 16